Zero-Clearance Fireplace Inserts ... The Solution for New Construction
is a Fireplace Insert hydronic heater that has a 30/50 heat distribution ratio. This means that around 30% of the rated heat output is radiated into the room where the unit is installed and around 50% of the rated heat output goes to the water.
Model Fi-BJ100 Specifications: TBD

Free-standing Unit - Model B100 specifications:
is an indoor hydronic heater that has a 50/30 heat distribution ratio. This means that around 50% of the rated heat output is radiated into the room where the unit is installed and around 30% of the rated heat output goes to the water.
 |
|
|
|
|
| |
|
High Burn* |
Low Burn* |
| Rated Heat Input |
BTU/Hr |
133,900 |
73,400 |
| Weight of cord wood |
Lbs |
44.5 |
42.2 |
| Max Wood length |
Inches |
20 |
|
| Glass Area Loading door |
Inches |
20.25 x 13 |
|
| Firebox Volume |
CF |
4.5 |
|
|
|
|
|
| Rated Overall Heat Output |
BTU/Hr |
104,500 |
60,200 |
| Heat to water |
BTU/Hr |
35,000 |
24,000 |
| Efficiency to water |
% |
26 |
33 |
| Heat into the room |
BTU/Hr |
69,500 |
36,200 |
| Efficiency to the room |
% |
52 |
49 |
| Overall efficiency |
% |
78 |
82 |
| Burn Time |
Hrs |
2.33 |
4.1 |
| Water Flow |
GPM |
6.2 |
6.2 |
| Max. Water Temp. |
F |
180 |
160 |
| Min. Water Temp. |
F |
130 |
130 |
 |
|
|
|
|
| Emissions* |
|
|
|
| Combustion concept |
Staged combustion with catalytic afterburn |
| Particulate Emission rate |
gr/Hr |
12.41 |
3.02 |
| Particulate Emission Factor |
gr/kg |
1.43 |
0.65 |
| Particulate Emissions Level |
Lb/MMBTU |
|
|
| CO |
ppm |
650 |
125 |
| CO2 |
% |
10 - 11 |
10 - 11 |
| O2 |
% |
10 - 13 |
10 - 13 |
| Max. Stack Temp. |
F |
320 |
225 |
| |
|
|
|
| Water Capacity |
Gallons |
5 |
|
| Maximum Operating Temperature |
F |
200 |
|
| Maximum Operating Pressure |
PSI |
30 |
|
| Test Pressure |
PSI |
85 |
|
| |
|
|
|
| Dimensional |
|
|
|
| Height |
Inches |
46 |
|
| Depth |
Inches |
26 |
|
| Width |
Inches |
28.5 |
|
| Weight |
Lbs |
875 |
|
| Flue Collar |
Inches |
8 |
|
| Built & Tested to the following Standards |
ASME IV, UL391, CAN/CSA B366.1 and UL 1482 |
| *Model B100 meets the EPA Hydronic Heater Program Phase II particulate emission level of max. 18 gr/hour. Model B100 can NOT be qualified to the EPA Hydronic Heater Program because this model can not be opereated at a burn rate for Category II. Testing performed by Intertek. |